Transmitters can be used for dozens of applications within industrial plants. They are designed to send a dependable signal no matter what the application.

When transmitters are used to send a data signal for liquids, pressure, or even pulse lines; they most often use a manifold block with sets of needle valves that allow certain lines to flow or be blocked off. These manifolds feed the media to the transmitter so that it can send its required signal.

Challenge

A huge challenge in the field though is keeping these manifolds from freezing. If they get too cold, the product within them cannot get to the transmitter and things start to shut down when the enterprise DCS/PLC or central control system cannot receive their required signals. There are only a couple of solutions available for this critical application.

Heat trace can't work, users can look at any of the instructions from any heat trace manufacturer, and not one of them publishes a set of directions for wrapping heat trace around this type of manifold. Heat trace installation instructions for all major manufacturers like Thermon, nVent (Raychem), Nelson, and Chromalox all show how to install heat trace on pipes, pumps, and valves but nothing on transmitters.

Heated boxes

Heating the air to heat the instrument isn’t the most effective method, but it works until it doesn’t

Heated boxes are the most commonly specified solution to keep manifolds working. Heated boxes consist of a poly box with a hinged door (top or side). A heater is installed inside the box. That heater heats the air in the box, and transmitters are warmed by the air.

Heating the air to heat the instrument isn’t the most effective method, but it works until it doesn’t. Heaters used to heat air and then heat a product have to work much harder than a heater that is custom fit right to the item being heated. It’s convective heat vs. conductive heat.

Manifold freezing

Air is a very poor heat transfer medium. Just go to any old timer at a power plant or refinery and ask if horseshoe heaters last very long. Wait for a very animated emotional response.

When users look at the transmitter assembly, the only thing that freezes is the manifold. The transmitter heads (normally called blue heads on site) are rated to really low ambient temperatures like -50F. They won't freeze. It’s the manifold that freezes up.

Solution: Powerblanket Transmitter heaters

Powerblanket units have heaters designed into the jacket walls, putting the heat right where it is needed

So what’s the best way to heat the manifold, by getting a heater right on it, while still allowing access to the needle valves, view displays, and calibration points? Powerblanket Transmitter heaters can be sized to fit directly over the head and manifold.

Powerblanket units have heaters designed into the jacket walls, putting the heat right where it is needed. Units can have access flaps or holes to accommodate conduit or process tubing. Straps or Velcro openings can be included for easy access, and then a nice tight fit once users close it back up.

Unit ranges

Powerblanket units can run off of 120, 208, or 240 Volts, and can be certified to class 1 division 2 groups A, B, C, or D, Class 2 Division 2 Groups E, F, or G, Class 3 Division 1 and T with a T rating of T3 through T6, as well as Class 1, Zone 2, IIC, and Class 2 Zone 22, IIIC, with a T3 to T6 Temperature rating.

(Can/CSA-C22.2 No 130, UL 499, UL 121201) or they can make a unit that is not certified to these standards.

In case you missed it

Mitsubishi Electric's Call For Energy Reform In UK
Mitsubishi Electric's Call For Energy Reform In UK

Despite 80% of UK homeowners saying they care about climate change, heat pump adoption in UK homes remains critically low, with only 6% making the switch. According to Mitsubishi...

Midea Equipping Contractors To Seize On The Transition To Heat Pumps
Midea Equipping Contractors To Seize On The Transition To Heat Pumps

The HVAC market is in transition. Heat pumps are no longer niche, but are becoming the default replacement for both furnaces and central AC. Midea is responding to the new normal a...

Carrier Corporation Unveils New Coolant Distribution Unit (CDU) For Data Centers
Carrier Corporation Unveils New Coolant Distribution Unit (CDU) For Data Centers

The new Carrier Coolant Distribution Unit, part of the growing QuantumLeap portfolio of purpose-built data center solutions that extends from chip to chiller, is now available. Car...

vfd