AET Flexible Space engineers have just completed a Cat-B fit-out of underfloor air conditioning equipment on the 5th floor of 180 Great Portland Street for a new incoming tenant, strategic communications specialist, Sard Verbinnen & Co. The Edwardian building, originally built for residential apartments was re-constructed in 2008, converting the restricted cellular floorplan to open plan, modern offices.

The building is accredited with the 2008 BCO Award for Innovation due to its sustainable design, with the introduction of underfloor air conditioning playing a major role in opening up the restrictive floor plates and maximizing floor-to-ceiling heights.

CAM-C chilled water system

The system installed throughout the six floors at 180 Great Portland Street is a CAM-C chilled water system with underfloor supply air and underfloor return air. The CAM-C downflow unit supplies conditioned air into the plenum beneath the raised access floor, which serves as the ventilation zone as well as space for power and IT distribution.

This zone is divided into supply and returns air paths using an airtight relocatable baffle, the CAM receives spent air back at floor level for re-conditioning, allowing for the total elimination of services located in the ceiling. Conditioned air is fed into the workspace using modular, relocatable TU4 Fantile units.

Additional Installation

AET supplied and installed additional equipment for the Cat-B fit-out on the 5th floor Working with Buckler Environmental on behalf of the fit-out lead, Loop Interiors, AET supplied and installed additional equipment for the Cat-B fit-out on the 5th floor. This included additional fan terminals, return air grilles, and underfloor air segregation baffle to accommodate the additional cooling requirements and cater to the new workspace layouts defined by the incoming tenant.

 The client also opted to install sound attenuator boxes beneath the grilles to minimize noise transfer between the open plan workspace, meeting rooms, and Director’s offices. User control of the underfloor air conditioning system is enhanced by the addition of seventeen wall-mounted Flextouch controllers, permitting remote temperature and fan speed adjustment of the Fantiles without having to physically access the integrated controller within the unit.

The fit-out works were handed over and new tenant SVC occupied the space early this month and the final result is a fabulous high-end, comfortable modern workspace.

In case you missed it

Mitsubishi Electric's Call For Energy Reform In UK
Mitsubishi Electric's Call For Energy Reform In UK

Despite 80% of UK homeowners saying they care about climate change, heat pump adoption in UK homes remains critically low, with only 6% making the switch. According to Mitsubishi...

Midea Equipping Contractors To Seize On The Transition To Heat Pumps
Midea Equipping Contractors To Seize On The Transition To Heat Pumps

The HVAC market is in transition. Heat pumps are no longer niche, but are becoming the default replacement for both furnaces and central AC. Midea is responding to the new normal a...

Carrier Corporation Unveils New Coolant Distribution Unit (CDU) For Data Centers
Carrier Corporation Unveils New Coolant Distribution Unit (CDU) For Data Centers

The new Carrier Coolant Distribution Unit, part of the growing QuantumLeap portfolio of purpose-built data center solutions that extends from chip to chiller, is now available. Car...

vfd