Rheem RKHL-C120CM15EDPJ Packaged Unit

Technical Specification

Features:
  • Make: Rheem
  • Model code: RKHL-C120CM15EDPJ
  • Series: RKHL
  • Electrical: 208-230/3/60 V/phase/Hz
  • Refrigerant Type: R-410a
Additional info:

H2AC™ Package Unit featuring eSync™ Integration Technology includes water circulation pump, refrigerant-to-water heat exchanger, and eSync Integration Technology control board for heat recovery during air conditioning mode to preheat potable water R-410A HFC refrigerant Complete factory charged, wired and run tested Scroll compressors with internal line break overload and high-pressure protection Single or dual stage available Downflow only TXV refrigerant metering system High Pressure and Low Pressure/Loss of charge protection standard on all models Solid Core liquid line filter drier Single slab, single pass designed evaporator and condenser coils facilitate easy cleaning for maintained high efficiencies Cooling operation up to 125 degree F ambient Foil faced insulation encapsulated throughout entire unit minimizes airborne fibers from the air stream Hinged major access door with heavy-duty gasketing, 1/4 turn latches and door retainers Slide Out Indoor fan assembly for added service convenience Powder Paint Finish meets ASTMB117 steel coated on each side for maximum protection G90 galvanized One piece top cover and one piece base pan with drawn supply and return opening for superior water management Forkable base rails for easy handling and lifting Single point electrical connections Internally sloped slide out condensate pan conforms to ASHRAE 62 standards High performance belt drive motor with variable pitch pulleys and quick adjust belt system Permanently lubricated evaporator and condenser motors Condenser motors are internally protected, totally enclosed with shaft down design 2 inch filter standard with slide out design 24 volt control system with resettable circuit breakers Colored and labeled wiring Copper tube/Aluminum Fin indoor coils with all aluminum MicroChannel condenser coil Supplemental electric heat provides 100% efficient heating Factory Installed ClearControl™, a Direct Digital Control (DDC) and sensors which can connect to LonWorks™ or BACnet® BAS systems for remote monitoring and control Pressure sensors provide refrigerant pressures, superheat, and subcooling on the ClearControl™ display H2AC Package Unit featuring eSync Integration Technology includes water circulation pump, refrigerant-to-water heat exchanger, and eSync Integration Technology control board for heat recovery during air conditioning mode to preheat potable water

Read more
Make Rheem
Manufacturer Rheem Manufacturing
Category Cooling>Packaged Units/RTU
Model code RKHL-C120CM15EDPJ
Series RKHL
Electrical 208-230/3/60 V/phase/Hz
Refrigerant Type R-410a
Weight 1151 lbs
Dimensions Height: 45.5 inches
Width: 60.63 inches
Depth: 95.19 inches
Additional info

H2AC™ Package Unit featuring eSync™ Integration Technology includes water circulation pump, refrigerant-to-water heat exchanger, and eSync Integration Technology control board for heat recovery during air conditioning mode to preheat potable water R-410A HFC refrigerant Complete factory charged, wired and run tested Scroll compressors with internal line break overload and high-pressure protection Single or dual stage available Downflow only TXV refrigerant metering system High Pressure and Low Pressure/Loss of charge protection standard on all models Solid Core liquid line filter drier Single slab, single pass designed evaporator and condenser coils facilitate easy cleaning for maintained high efficiencies Cooling operation up to 125 degree F ambient Foil faced insulation encapsulated throughout entire unit minimizes airborne fibers from the air stream Hinged major access door with heavy-duty gasketing, 1/4 turn latches and door retainers Slide Out Indoor fan assembly for added service convenience Powder Paint Finish meets ASTMB117 steel coated on each side for maximum protection G90 galvanized One piece top cover and one piece base pan with drawn supply and return opening for superior water management Forkable base rails for easy handling and lifting Single point electrical connections Internally sloped slide out condensate pan conforms to ASHRAE 62 standards High performance belt drive motor with variable pitch pulleys and quick adjust belt system Permanently lubricated evaporator and condenser motors Condenser motors are internally protected, totally enclosed with shaft down design 2 inch filter standard with slide out design 24 volt control system with resettable circuit breakers Colored and labeled wiring Copper tube/Aluminum Fin indoor coils with all aluminum MicroChannel condenser coil Supplemental electric heat provides 100% efficient heating Factory Installed ClearControl™, a Direct Digital Control (DDC) and sensors which can connect to LonWorks™ or BACnet® BAS systems for remote monitoring and control Pressure sensors provide refrigerant pressures, superheat, and subcooling on the ClearControl™ display H2AC Package Unit featuring eSync Integration Technology includes water circulation pump, refrigerant-to-water heat exchanger, and eSync Integration Technology control board for heat recovery during air conditioning mode to preheat potable water

Download PDF version Download PDF version
vfd