SPX Cooling Tech, LLC, a full-line, full-service industry leader in the design and manufacture of evaporative cooling towers and air-cooled heat exchangers, has introduced the Marley® CoolBoost™ Opti FC Control Panel, a new and intuitive control system designed for Marley MH and DT fluid cooler models.

CoolBoost Opti FC gives users the ability to optimize their system’s performance with flexible operating modes designed to conserve energy or water, depending on the selected mode.

Wet-Priority modes

The modern features of the CoolBoost Opti FC interface – the touchscreen and the easy-to-use comprehensive status view – are almost enough to distract from its most-impressive feature: it allows operators to select dry-priority or wet-priority modes for saving water or energy, when necessary,” explained Aaron Todd, Product Development Lead with SPX Cooling Tech.

The control panel gives operators the option to choose one of four modes: Wet First, Dry First, Wet Only or Dry Only. Wet First and Dry First modes allow users to setup a staging effect for when the pump and fan are turned on and off based on system requirements and environmental factors. Wet Only and Dry Only modes let the fluid cooler operate without the use of the pump or the fan respectively.

Selectable control options

The CoolBoost Opti FC panel is also BACnet communication compatible

Other features of the control panel include an integral PLC for selectable control options – including Auto, Hand, and Off – and BMS integration capabilities that allow for remote or local system control. The CoolBoost Opti FC panel is also BACnet communication compatible, simplifying integration into BMS systems for monitoring, control, and saving historical data.

Another big plus for CoolBoost Opti FC users is its single-point power connection, which eliminates panel design time and could save significant installation hours, and the electrician costs associated with them,” added Todd.

Tagout safety requirements

The control panel itself is constructed with a NEMA 3R painted enclosure – or can be made as optional NEMA 4X fiberglass or stainless-steel enclosure – that includes an external disconnect handle with padlocking provision to meet lockout/tagout safety requirements.

It is built to UL508 and cUL508 safety requirements. A protective cover is also provided to guard the HMI screen from the elements. The CoolBoost Opti FC Control Panel is available now with select Marley fluid coolers.

Download PDF version Download PDF version

In case you missed it

Johnson Controls On Financial Times Europe Climate Leaders List
Johnson Controls On Financial Times Europe Climate Leaders List

Johnson Controls, the global pioneer for smart, healthy and sustainable buildings, has again been named to the Financial Times Europe Climate Leaders list in 2024. This marks...

How Finalized SNAP Rule 26 Will Impact Uses Of Commercial Refrigerants
How Finalized SNAP Rule 26 Will Impact Uses Of Commercial Refrigerants

SNAP Rule 26 marks an important milestone in the transition from commercial refrigeration to new refrigerants. The rule lists refrigerant substitutes that provide a spectrum of tec...

Carrier Cooling-As-A-Service For Enhanced HVAC Solutions
Carrier Cooling-As-A-Service For Enhanced HVAC Solutions

Carrier is pleased to announce Carrier Cooling-as-a-Service, a portfolio of innovative solutions to help commercial customers simplify the operation of HVAC and other thermal or el...

vfd